TM 5-6675-324-14
Table 3-5. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
35. DEVELOPER OUT/WASTE DEVELOPER INDICATOR FLASHES EVEN THOUGH RESERVOIR CON-
TAINS ENOUGH DEVELOPER AND WASTE RECEPTACLE IS NOT FULL.
Step 1.
Cleaner overflow detector is covered by developer.
Step 2.
Cleaner overflow detector lamp is defective.
Dc controller PC board is defective.
Step 3.
Display PC board is defective.
Step 4.
36. DEVELOPER OUT/WASTE DEVELOPER INDICATOR DOES NOT FLASH WHEN THERE IS NO
DEVELOPER IN RESERVOIR OR WHEN IT IS OVERFLOWING IN CLEANER ASSEMBLY.
Step 1.
Developer reservoir detector is covered by developer.
Developer reservoir detector is defective.
Step 2.
Cassette paper detector photocell is defective.
Step 3.
Dc controller PC board is defective.
Step 4.
Display PC board is defective.
Step 5.
3-124