Locate plugged access hole for right light grid and for left light
e.
grid, and remove plug for hole to be used.
Insert insulated alinement tool through hole to engage adjusting
f.
screw on high level resistor. Turn screw until light output is
2000 ft lamberts.
(Light is still on at minimum
g.
intensity.)
h.
Turn low resistor adjusting screw until intensity is 500 ft lamberts.
Recheck high value (2000 ft lamberts) with illumination control fully
i.
right.
Readjust high and low values until range of intensity is low, 500 ft
j.
lamberts, and high, 2000 ft lamberts. Turn off lights.
k.
Reinstall
plugs.
l.
Turn fan motor control switch to off.
m.
U n p l u g power cord.