TM 5-6675-323-14
4-10.1 Adjust Platform Spring Tension.
MOS: 81Q, Terrain Analyst
a.
Fully open left door, remove spring adjusting crank.
b.
Remove locking screw. Retain for reuse.
c.
Place microscan on turntable.
d.
Insert crank into square hole under table.
NOTE
Initial tension of spring is 100 right turns of crank, when spring has
been fully relaxed.
e. Turn crank to left or right to change tension. Turning to right
increases tension and turning to left decreases tension.
WARNING
To prevent injury, use two hands to hold table when raising.
f. Grasp front of platform with two hands, and apply downward force
while pulling table out. Table should raise without excessive
force.
Lift front of platform and push down to bottom of travel. Then push
g.
all the way to rear. Readjust spring tension as required by turning
crank.
h.
Replace spring adjusting crank.
4-22 Change 1