TM 5-6675-323-14
Input to the plotter is from a desktop
c o m p u t e r t h r o u g h a n H P - I B I n t e r f a c e b u s . T h e ADDRESS switch setting on the inter-
c o n n e c t PCA determines the bus address that the plotter will respond to. When
addressed to transfer data or status, the HP-IB circuitry sets up the data transfer
and provides the interface between the plotter microprocessor and the controller.
(1) Data transfer is controlled by the processor circuitry which generates
the appropriate timing signals to properly sequence the processing of data and
instructions on the plotter bus.
(2) In the memory circuitry, the read only memories (ROMs) store the
instructions and data constants which the processor accesses and interprets. The
r a n d o m access memories (RAMs) are used for temporary storage of microprocessor
calculations and for input/output data.
(3) The internal I/O circuitry provides an interface between the front panel
PCA circuitry and the plotter bus and also passes velocity information from the
(4) The interpolator circuits accept velocity information generated in the
processor and convert this information from digital format to the analog waveforms
required by the motor drivers for the X- and Y-axis motors.
(5) The motor drivers provide both voltage and power amplifications for the
T h e s e signals drive the X-
analog signals generated by the interpolator circuits.
and Y-axis plotter motors.
3-119