TM 5-6675-323-14
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
(Number) - Hundreds of Hours
AN - Annually
W - Weekly
B - Before
S - Semiannually
M - Monthly
D - During
BI - Biennially
Q - Quarterly
A - After
For Readiness
I N - ITEM TO BE INSPECTED
Reporting,
Equipment Is
ITEM TER-
PROCEDURE
Not Ready!
NO.
VAL
Available If:
VAN BODY - Cont
Inspect Exterior - Cont
1
Ground
8.
Visually inspect ground connections to be sure
B/W
connec-
g r o u n d cable is connected to terminal lug and
tions are
If necessary, clean:
ground rod.
b r o k e n or
missing.
WARNING
be de-energized before servicing entry panel
Death can result from failure to
connections.
observe these safety precautions.
Turn power off to cable. Disconnect from power
a.
source.
Disconnect ground lug from ground rod.
b.
Clean lug, cable end, and rod with wire brush.
c.
Reconnect ground cable lug to rod.
d.
Disconnect ground cable end from entry panel.
e.
f.
Clean terminal and cable end with wire brush.
Reconnect ground cable to entry panel.
g.
Reconnect cable to power source. Turn power on.
h.
Steps are
Inspect boarding ladders for:
9.
B
b r o k e n or
will not
Secure attachment of handrails.
a.
lock in
place.
b. Steps not broken.
c.
Locking pins in place.
1-18