TM 5-6675-321-14
a.
Drill pop rivets from hinged cover to remove vent cover .
b. Remove defective vent cover and transfer mounted hardware to new cover.
WARNING
Dry cleaning solvent, P-D-680 used to clean parts is potentially dan-
gerous to personnel and property. Avoid repeated and prolonged skin
contact. Wear solvent-impermeable gloves and eye/face protective
equipment when using solvent. Do not use near open flame or excessive
h e a t . F l a s h p o i n t o f s o l v e n t i s 1 0 0 ° F t o 1 3 8 ° F ( 3 8 ° C t o 5 9 ° C ) .
c .
Scrape gasket off section and clean area with solvent P-D-680.
d. Secure new gasket to section with adhesive.
e.
Aline ventilation fan vent cover and pop rivet to hinge.
f . T e s t c o v e r f o r t i g h t n e s s o f c l o s u r e .
1-73