TM 5-6675-321-14
n.
As soon as wax is soft enough, insert dial thermometer into wax tray.
Push stem as far under coating as it will go.
o.
Rest dial thermometer on edge of wax tray.
p.
Stem should rest approximately in center of tray.
q.
When thermometer reaches 210°- 220°F (approximately 10 min),
immediately turn override thermostat adjusting screw to the right slowly
u n t i l i n n e r p i l o t l i g h t g o e s o u t.
r .
Override thermostat is now set.
s.
When wax on coating roller appears melted (approximately 10 min from
start), slowly turn motor adjusting screw to the right until amber
OPERATE pilot light on front panel lights.
t .
After motor thermostat is set, wait approximately 15 min for temperature
t o s t a b i l i z e.
4-69