TM 5-6675-321-14
4 - 2 0 . 7 A d j u s t T h e r m o s t a t s.
MOS:
83FJ6, Reproduction Equipment Repairer
TOOLS:
Flat Tip Screwdriver
Dial Thermometer
WARNING
Serious injury may occur if internal components are touched when heat is on.
Remove heat source and allow to cool, or wear protective clothing before
s e r v i c i n g .
Death or serious injury may occur from electrical shock unless power
cord is unplugged before servicing.
NOTE
This procedure must begin with wax coater completely cool. If it has been
used, allow machine to cool for at least two hours with power OFF.
a.
Unplug
b. Remove
power cord.
top deck cover and top roller cover.
c .
Set LOW/HIGH thermostat to position 1.