TM 5-6675-32014
c.
Unplug electrostatic platen plug.
d. Position pen arm at extreme right end of plotter.
NOTE
When retaining screws are removed from platen, it will fall. Place
supporting material under platen before removing all screws.
e .
Remove six screws around edge of platen and two screws from center of
p l a t e n.
f. Lift defective platen out carefully from end opposite pen arm.
g.
Install new platen and secure with eight screws.
h . P l u g i n e l e c t r o s t a t i c p l a t e n p l u g.
i .
Lower upper deck assembly and reinstall rear hood.
4-275