TM 5-6675-320-14
Table 1-1.
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
lN-
TER-
VAL
B
ITEM TO BE INSPECTED
PROCEDURE
B - Before
W - Weekly
AN - Annually
D - During
M - Monthly
S
- Semiannually
(Number) - Hundreds of Hours
A - After
Q - Quarterly
BI
- Biennially
lTEM
NO.
1
VAN BODY - Cont
Inspect Exterior - Cont
WARNING
a.
b .
c .
d .
e.
f .
g .
h .
9 .
a.
b.
c .
Electrical shock hazard. Power cable must
be deenergized before servicing entry panel
connections. Death can result from failure to
observe these safety precautions.
Turn power off to power cable. Disconnect
from power source.
Disconnect ground lug from ground rod.
Clean lug, ground cable end, and rod with
w i r e b r u s h.
Reconnect ground cable lug to rod.
Disconnect ground cable end from entry panel.
Clean terminal and ground cable end with
w i r e b r u s h .
Reconnect ground cable end to entry panel.
Reconnect power cable to power source.
Turn power on.
Inspect boarding ladders for:
Secure attachment of handrails.
Steps not broken.
Locking pins in place.
For Readiness
Reporting,
Equipment Is
Not Ready/
Available If:
Steps are
broken or
w i l l n o t
l o c k in
place.
1-18