TM 5-6675-320-14
C o n t r o l o r I n d i c a t o r
Function
HP-l B Cable Receptacle
Logic Address Switches
CONFIDENCE TEST/LISTEN ONLY Switch
HP-IB Interface cable
24-pin receptacle .
Set address of plotter
f o r c o n t r o l l e r . S e t a t
f a c t o r y t o 5.
When set to 0, LISTEN
ONLY switch allows plot-
t e r t o t a l k t o c o n t r o l-
l e r a n d l i s t e n . A l l o w s
p l o t t e r t o l i s t e n o n ly
when set to I. Set to 0
for normal operation.
CONFIDENCE TEST switch
activates confidence test
when set to I.
4 - 48