TM 5-6675-320-14
C o n t r o l o r I n d i c a t or
Function
ENTER Push Button
Scaling Point Control Push Buttons
Pressing either moves pen
to corresponding physical
point, P1 or P2, on pla-
t e n.
When the plotter is
i n i t i a l i z e d , i t s e t s P 1
at lower left corner and
P2 at upper right corner
o f p l a t e n.
Pressing
ENTER, P1, or P2 relo-
c a t e s t h a t s c a l i n g p o i nt
to current pen location.
Multi-purpose button with
lamp:
Pushed before CHART HOLD,
i t i n i t i a l i z e s p l o t t e r .
( l a m p b l i n k s .)
Pushed before P1 or
P2, it sets new
s c a l i n g p o i n t s .
( l a m p b l i n k s . )
Used to enter point
i n d i g i t i z i n g m o d e.
(lamp is steady.)
Used with pen select
buttons to store
p e n i n i t s s t a b l e.
NOTE
Pushing any of pen
c o n t r o l a r r o w s c a n-
cels ENTER lamp.
4-44