TM 5-6675-320-14
WARNING
U s e h o i s t o r p r o p e r l i f t i n g e q u i p m e n t t o r e p l a c e a i r c o n d i t i o n e r / h e a t e r.
Failure to do so may result in death or serious injury.
Turn off air conditioner/heater circuit breaker and unplug power cord.
Failure to do so may result in death or serious injury .
a.
b.
c .
d.
e .
f .
g .
h.
i .
T u r n o f f a i r c o n d i t i o n e r / h e a t e r c i r c u i t b r e a k e r . U n p l u g o r d i s c o n n e ct
power cord as appropriate.
Remove screws holding air duct to air conditioner/heater.
Remove nut, washer, and screw from each corner of air conditioner/heater
mounting.
Remove screws securing mounting to section.
Disconnect drain line from air conditioner/heater.
A t t a c h s l i n g t o l i f t i n g h a n d l e s.
Raise hoist enough to remove slack
f r o m s l i n g.
Remove mounting bolts and washers.
S l i d e o u t a i r c o n d i t i o n e r u n t i l o t h e r l i f t i n g h a n d l e s a r e f r e e . A t t a c h
sling to handles.
R a i s e d e f e c t i v e a i r c o n d i t i o n e r / h e a t e r w i t h h o i s t u n t i l u n i t i s f r ee
from brackets and section.
P l a c e a i r c o n d i t i o n e r / h e a t e r o n f l a t - b e d t r u c k o r p a l l e t.
WARNING
Dry cleaning solvent,
P-D-680, used to clean parts is potentially danger-
ous to personnel and property.
Avoid repeated and prolonged skin contact.
Wear solvent-impermeable gloves and eye/face protective equipment when
using solvent.
Do not use near open flame or excessive heat. Flash point
of solvent is 100° F to 138° F (38° C to 59° C).
j .
Clean sealant from opening using dry cleaning solvent P-D-680.
k. Remove damaged gasket and replace with new gasket.
1.
R a i s e a i r c o n d i t i o n e r / h e a t e r u n t i l i t r e s t s o n a i r c o n d i t i o n e r / h e a t e r
b r a c k e t s .
m.
Remove two sling hooks as unit is eased into hole until grille touches
d u c t .
n .
Remove remaining sling.
1-101