TM 5- 6675-319-14
1-16.1 R e p l ac e Fluorescent Lamp Ballast.
MOS: 83FJ6, Reproduction Equipment Repairer
416, Topographic Instrument Repair Specialist
TOOLS :
Flat Tip Screwdriver
1/4 in. Wrench
1/4 in. Drive Socket Set
S c r i be
SUPPLIES:
Lamp Ballast
Wire Ties
WARNING
Death or serious injury may occur unless overhead light circuit breaker
and main circuit breaker are turned off before working on light fixture .
a.
Turn off overhead light, circuit breaker and main circuit breaker.
b . R e m o v e d i f f u s e r f r o m l i g h t fi
c .
Remove safety tabs and lamps
d. Squeeze light wire guard and
x t u r e .
P l a c e i n d i f f u s e r.
remove.
e .
Remove wire ties as required.
f . T a g w i r e s f r o m b a l l a s t f o r r e f e r e n c e.
Change 1