TM 5-6675-319-14
Table 9-5. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
15.
APL MOTOR WILL NOT RUN UNDER ANY CONDITION . PRINTER WORKS NORMALLY IN
SINGLE-PRINT OPERATION. RPT WORKS - Cont
Step 2.
With power on and equipment set for APL operation, check for
the presence of 115 V ac.
If 115 V ac is present,
replace APL motor B201 (paragraph 9-20.4).
16.
INAPL OPERATION, DOUBLE OR TRIPLE EXPOSURE FREQUENTLY OCCURS. PRINTER
WORKS CORRECTLY FOR SINGLE-PRINT OPERATION.
Step 1.
Check output of printed circuit card 4TC-1.
( a ) I f o u t p u t i s c o r r e c t ,
( b ) I f i n c o r r e c t , r e p l a ce
Step 2.
Check operation of APL motor
I f o p e r a t i o n i s i n c o r r e c t,
proceed to step 2.
4TC-1 card (paragraph 9-20.2).
B201 .
replace APL motor (paragraph 9-20.4).