TM 5-6675-319-14
Table 9-5. DIRECT/GENERAL
SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
13.
APL MOTOR RUNS CONTINUOUSLY WHEN LIFTER POWER IS ON. WILL NOT EXPOSE IN
AUTOMATIC OR MANUAL MODES WITH LIFTER POWER OFF.
Check for proper operation of 4TC-1 card.
If operation is incorrect, replace 4TC - 1 card (paragraph 9-20.2).
14. APL MOTOR CYCLES THROUGH EXPOSURE MODE WITHOUT STOPPING. STOPS ON RPT AD-
VANCE. WILL NOT EXPOSE IN AUTOMATIC OR MANUAL MODES. OPERATES CORRECTLY IN
TEST.
Step 1.
Check that cycle switch S202 closes at bottom of APL stroke.
(a) If S202 is correctly adjusted, proceed to step 2.
( b ) A d j u s t S 2 0 2.
Step 2.
With power OFF, check for continuity between TS201-12 to J201-10.
If no continuity is present, replace S202 (paragraph 9-20.3).
9-122