TM 5-6675-319-14
WARNING
Death or serious injury may occur from electrical shock unless power cord
is unplugged before servicing.
a.
Turn power switch off, and unplug power cord.
b. Remove one screw from each of four clips. Loosen other screws.
c .
T u r n c l i p s 9 0 ° t o l e f t o r r i g h t .
CAUTION
Glass surface must be handled with care to avoid chipping or breaking.
d. Remove glass surface and set aside.
e.
Remove screws and front cover panel.
f. Remove bezel nut, label, and nut from
NOTE
power switch.
Ground wire is not connected to switch.
M a r k p o s i t i o n f o r r e i n s t a l l a t i o n.
g.
To remove defective power switch, pull to inside of board. Tag and
disconnect wires.
h. Remove defective switch.
i .
Connect wiring to new power switch and remove tags.
j .
R e i n s t a l l n u t , l a b e l , a n d b e z e l n u t.
A d j u s t f o r p r o p e r p o s i t i o n i n g of
power switch.
k. Reinstall front cover panel and secure with screws.
l .
R e i n s t a l l g l a s s s u r f a c e.
m.
Turn clips 90° to secure glass surface.
n.
R e i n s t a l l s c r e w s o n c l i p s . T i g h t e n a l l s c r e w s.
o.
Plug in power cord, and turn power switch on.
6-17