TM 5-6675-319-14
Table 2-1.
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
B - Before
W - Weekly
AN - Annually
(Number)
- Hundreds of Hours
D - During
M - Monthly
S
- Semianually
A - After
ITEM
NO.
5
6
lN-
TER-
VAL
B
B
Q - Quarterly
BI - Biennially
ITEM TO BE INSPECTED
PROCEDURE
FILM/PAPER PROCESSOR SYSTEM - Cont
Inspect Dryer System - Cont
Turn on DRYER switch.
Blower fan should rotate.
Inspect Developer Thermometer.
NOTE
Allow processor to run for 30 minutes to
stabilize developer temperature.
Check developer temperature with DEVELOPER thermo-
mometer and verify temperature is 80°F (27°C). If
not, remove cover and adjust temperature by turning
DEVELOPER thermostat to right for more heat and to
l e f t f o r l e s s h e a t.
Glow lamp indicates developer
heater is on.
For Readiness
Reporting,
Equipment Is
Not Ready/
Available If:
Blower fan
does not
r o t a t e.
Temperature
cannot be
adjusted.
2-21