TM 5-6675-318-14
Table 3-24.
DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
PLOTTER DOES NOT RESPOND TO COMMANDS OR GENERATES "ERROR" FOR EACH
8.
INSTRUCTION - Cont
Step 15. C o m p a r e o u t p u t o f d i s p l a y a n d p r i n t o u t t o a b o v e i l l u s t r a t i o n t o
be sure test has run correctly.
Step 16.
If test is not correct, compare displayed or printed error and
25 lists the HP-IB tests. Test will halt on failed portion.
Step 17.
If test is positive (no errors), repeat steps 1-4 on tested inter-
face and restore switches to their factory settings, as follows:
Select code switch to 7.
Parallel poll bit to 1.
Talk/Listen ADDRESS switches to on, off, on, off, on, and off.
System controller to ON.
Parallel poll logic stops on I.
If test failed, replace HP-IB.
Step 18. R e p e a t s t e p s 5 a n d 6 , a n d r e a s s e m b l e H P - I B I n t e r f a c e .
POWER SUPPLY FAILURE.
9.
Step 1.
R e m o v e HP-IB Interface from plotter.
S t e p 2.
Turn LINE power switch to on (I).
WARNING
Death or serious injury may occur from electrical shock. Be careful not
insulated floor or mat.
3-240