TM 5-6675-318-14
Table 3-9. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
AN - Annually
B - Before
W - Weekly
(Number) - Hundreds of Hours
S - Semiannually
M - Monthly
D - During
BI - Biennially
Q - Quarterly
A - After
For Readiness
ITEM TO BE INSPECTED
Reporting,
IN-
lTEM
Equipment Is
TER.
PROCEDURE
NO
Not Ready/
VAL
Available If:
GRAPHICS PLOTTER - Cont
Clean - Cont
2
W
4.
Apply cleaner (Hewlett-Packard or commercial
cleaner) to cloth and wipe platen surface.
5.
Wipe platen thoroughly with clean, damp cloth.
6.
W i p e away any moisture from platen surface with dry
cloth.
Allow plotter to dry before use.
7.
Remove fan filter by pulling gently from top two
corners.
Wash filter thoroughly with soapy water.
Wring out all moisture and allow to dry before
replacing.
Plotting Repeatability and Accuracy Test.
M
3
1.
Load plotter with blank chart paper. Place new
p e n in pen arm.
2.
Enter program on illustration into calculator and
r u n program.
3-55