TM 5-6675-318-14
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
Table 1-1.
(Number) - Hundreds of Hours
AN - Annually
W - Weekly
B - Before
S - Semiannually
D- During
M - Monthly
B l - Biennially
Q - Quarterly
A After
For Readiness
ITEM TO BE INSPECTED
Reporting,
IN-
Equipment Is
ITEM
TER-
PROCEDURE
Not Ready/
NO.
VAL
Available If:
VAN BODY - Cont
Inspect Exterior - Cont
1
WARNING
be deenergized before servicing entry panel
Death can result from failure to
connections.
observe these safety precautions.
a.
Turn power off to cable. Disconnect from power
source.
b.
Disconnect ground lug from ground rod.
c.
Clean lug, cable end, and rod with wire brush.
d.
Reconnect ground cable lug to rod.
e.
Disconnect ground cable end from entry panel.
f. Clean terminal and cable end with wire brush.
Reconnect ground cable to entry panel.
g.
h.
Reconnect cable to power source. Turn power on.
Steps are
9.
Inspect boarding ladders for:
B
b r o k e n or
will not
a.
Secure attachment of handrails.
lock in
place.
b. Steps not broken.
c.
Locking pins in place.