TM 5-6675-317-14
1-16.10 Replace Ventilation Fan Cover.
MOS :
83FJ6, Reproduction Equipment Repairer
TOOLS:
Drill and Bits
Pop Rivet Gun
Scraper
SUPPLIES:
Pop Rivets
Ventilation Fan Cover
Gasket
Solvent P-D-680 (Item 72, Appendix E)
Adhesive (Item 1, Appendix E)
Cheesecloth (Item 16, Appendix E)
Impermeable Gloves
Goggles
a. Drill pop rivets from hinged cover to remove vent cover.
b.
Remove defective vent cover and transfer mounted hardware to new cover.
WARNING
Dry cleaning solvent, P-D-680 used to clean parts is potentially dan-
gerous to personnel and property.
Avoid repeated and prolonged skin
contact.
Wear solvent-impermeable gloves and eye/face protective
equipment when using solvent.
Do not use near open flame or excessive
heat.
Flash point of solvent is 100° F to 138° F (38° C to 59° C).
c. Scrape gasket off section and clean area with solvent P-D-680.
d.
Secure new gasket to section with adhesive.
e. Aline ventilation fan vent cover and pop rivet to hinge.
f.
Test cover for tightness of closure.
Change 1