8-7. OPERATION UNDER UNUSUAL
TM 5-6675-317-14
CONDITIONS. This equipment is designed for use
only in a controlled environment.
Section Ill OPERATOR MAINTENANCE
8-8. LUBRICATION INSTRUCTIONS. This equipment does not require lubrication.
8-9. TROUBLESHOOTING PROCEDURES.
a.
The table lists the common malfunctions which you may find during the
operator maintenance of the support equipment.
You should perform the
test/inspection and corrective actions in the order.
b.
This manual cannot list all the possible malfunctions or every possible
test/inspection and corrective action.
If a malfunction is not listed or corrected
by a listed corrective action, notify your supervisor.
Table 8-2. TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
MAGNIFIER LAMP WILL NOT LIGHT.
Check that Magnifier Lamp is plugged into active power outlet. Press
switch OFF then ON.
(a) If lamp still does not come on, replace tube.
(b) If new tube does not light, refer to organizational
maintenance.
2.
VACUUM CLEANER MOTOR DOES NOT OPERATE.
Step 1.
Check power cord.
(a) If plugged in, proceed to step 2.
(b) Plug in power cord.
8-17