TM 5-6675-317-14
Table 1-1.
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
B - Before
W - Weekly
AN - Annually
(Number) - Hundreds of Hours
D - During
M - Monthly
S
A - After
- Semiannually
Q - Quarterly
BI - Biennially
ITEM
No.
1
IN-
TER-
VAL
ITEM TO BE INSPECTED
PROCEDURE
VAN BODY
Inspect Exterior - Cont
8.
9.
10.
Visually inspect ground connections to be sure
grounding cable is connected to terminal lug and
grounding rod. If necessary, clean:
WARNING
Electrical shock hazard. Power
cable must be de-energized before
servicing entry panel connections.
Death can result from failure to
observe these safety precautions.
a.
Turn power off to cable. Disconnect from power
source.
b.
Disconnect grounding lug from grounding rod.
c.
Clean lug, cable end, and rod with wire brush.
d.
Reconnect grounding cable lug to rod.
e.
Disconnect grounding cable end from entry panel.
f.
Clean terminal and cable end with wire brush.
9.
Reconnect grounding cable to entry panel.
h.
Reconnect cable to power source. Turn power on.
Inspect boarding ladders for:
a.
Secure attachment of handrails.
b.
Steps not broken.
c.
Locking pins in place.
Inspect front and rear van body locks to be sure
locks are fully engaged.
For Readiness
Reporting,
Equipment Is
Not Ready/
Available If:
Grounding
connec-
tions are
broken or
missing.
Steps are
broken or
will not
lock in
place.
Lock dis-
engaged.
1-17