TM 5-6675-317-14
Section III
OPERATOR MAINTENANCE
3-8. LUBRICATION INSTRUCTIONS. This equipment does not require lubrication.
3-9. TROUBLESHOOTING PROCEDURES.
a.
The table lists the common malfunctions which you may find during operation
or maintenance of the stereo zoom transfer scope, or its components.
YOU should
perform the test/inspections and corrective actions in the order listed.
b.
This manual cannot list all malfunctions that may occur, nor all test or
inspections and corrective actions.
If a malfunction is not listed or is not
corrected by listed corrective actions, notify your supervisor.
Table 3-2. TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
NO ILLUMINATION.
Step 1.
Check that controller to stereoscope power cord is plugged in.
(a) If cord
(b) Plug in
Step 2.
Check that the
outlet.
(a) If cord
(b) Plug in
is plugged in, proceed to step 2.
power cord.
controller power cord is plugged into an active
is plugged in, proceed to step 3.
power cord.
Step 3.
Check that circuit breaker is ON.
(a) If circuit breaker is ON, proceed to step 4.
(b) Reset circuit breaker.
(c) If circuit breaker trips repeatedly, notify power supply
supervisor.
3-29