(b) Mount pen lifting device. If tangentially controlled device is to be used, mount pen lifting device on
side of adapter with two mounting screws as shown. Plug power cord into jack on front of X-carriage (table 3-5,
item 1).
b. Setting (DKA3) XY display for operation.
NOTE
Prior to any procedure using XY display, display must be set by selecting
measurement system, scale factors, and preset values via keyboard.
(1) Select zero point or origin of drawing or tracing to be worked. Position tool or pen point over this spot by
moving cartridges.
(2) Turn locking knobs to secure carriages in place. Adjust position of carriages by turning fine adjustment
knob.
(3) Zero and reset XY display by pressing white reset button. Check that XY display shows two lines of
zeros.
Change 1
3-63