TM 5-6675-316-14
Table 4-1.
OPERATOR PREVENTIVE MAINTENANCE CHECKS
B - Before
W - Weekly
AN - Annually
D - During
M - Monthly
s
- Semiannually
A - After
Q - Quarterly
BI - Biennially
lTEM
NO.
8
9
lN-
TER-
VAL
B
B
AND SERVICES - Cont
(Number) - Hundreds of Hours
ITEM TO BE INSPECTED
PROCEDURE
SPLIT-STAGE LIGHT TABLE - Cont
Inspect Z-Axis Course Feed Knob and Z-Axis Fine
Feed Knob.
Rotate both controls and check that optical mount
moves up and down freely.
WARNING
Do not use equipment with defective or worn
wiring.
Death or serious injury may result.
Inspect Power Cord and Wiring.
Inspect for breaks, tears, frayed or broken
connectors.
For Readiness
Reporting,
Equipment Is
Not Ready/
Available if:
Z-axis binds.
Wiring is
defective or
worn.
4-16