TM 5-6675-316-14
Place negative lead on TP4; positive lead on TP2.
f.
Adjust R8 for +5 0.01 V.
g.
Remove positive lead from TP2 and negative lead from TP4.
h.
i.
Connect negative lead to TP4 and positive lead to TP1.
j.
k.
Adjust R36 for -12 0.01 V.
1.
Reinstall front panels.
m.
Place power switch to OFF.
n.
o.
Reinstall top left panel.
Perform diagnostic test.
P.
2-291