TM 5-6675-315-14
1-16.6 Replace Receptacle.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS: Flat Tip Screwdriver
SUPPLIES: Receptacle
WARNING
Death or serious injury may result if receptacle circuit breaker is not turned off before working on
receptacle.
a. Turn off receptacle circuit breaker.
b.
Remove cover plate screws.
c.
Remove cover plate.
d.
Remove mounting screws.
e.
Withdraw receptacle to gain access to wires.
f.
Loosen terminal screws and ground screw. Then disconnect wires.
g.
Install new receptacle.
1-69