TM 5-6675-315-14
Table 1-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
B - Before
W - Weekly
AN - Annually
(Number) - Hundreds of Hours
D - During
M - Monthly
S - Semiannually
A - After
Q - Quarterly
BI - Biennially
ITEM TO BE INSPECTED
For Readiness
IN
Reporting
ITEM
TER-
PROCEDURE
Equipment Is
NO.
VAL
Not Ready/
Available If:
VAN BODY - Cont
1
Inspect Exterior - Cont
Q
11.
Inspect personnel door gaskets for leaks or
damage.
W
11.1
Inspect hinges for proper placement of
Missing
hinge pins.
hinge pins.
12.
Clean and paint blistered, pitted, or flaking
areas and bare metal spots in accordance with
instructions contained in TM 43-0139, Painting
Instructions for Field Use.
2
Inspect Interior.
B/D
1.
Test emergency lights by pressing test button.
Emergency
lights do
not light.
W
2.
Inspect power cords and cables to be sure wires
Wires or
are not kinked, cut, or cracked.
cables are
cracked or
W
3.
Inspect plug connectors to be sure all plug
cut.
connectors are tight and firmly seated. Tighten
if necessary.
D
4.
Inspect for burned out light bulbs and
fluorescent tubes. Replace as required.
W
5.
Inspect walls, ceilings, and floor for holes,
Leaks are
open seams, or signs of seepage or leaks.
present.
D
6.
Check storage cabinets for broken hinges,
Broken hinge/
latches, and locks.
latch/lock.
B/M/
7.
Inspect fire extinguishers. Be sure security
Fire extin-
A
seals are not broken.
guisher is
missing or
seals are
broken.
Change 2 1-18