TM 5-6675-313-14
Table 1-1.
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
B - Before
W - Weekly
AN - Annually
(Number) -
D - During
Hundreds of Hours
M - Monthly
S
- Semiannually
A - After
Q - Quarterly
BI - Biennially
ITEM
NO.
2
3
4
VA L
B/W
B
M
ITEM TO BE INSPECTED
PROCEDURE
VAN BODY - Cont
Inspect Interior - Cont
12.
Inspect blackout curtains.
a.
Inspect blackout curtains and valances for
tears, missing hooks, or broken eyelets.
b.
Inspect nylon hook and pile tape on curtain
and wall for security of attachment.
Inspect Air Conditioner/Heater. Refer to TM 5-4120-
6/-14 for preventive maintenance checks and services.
Service Power Cable.
WARNING
Electrical shock hazard. Power cable must be de-
energized before servicing. Death or serious
injury may occur from failure to observe this
safety precaution.
1.
Turn off safety switch.
2.
Disconnect cable from power entry panel.
3.
Wrap any cuts or abrasions in cable with electrical
insulation tape.
NOTE
Check to be sure cable does not endanger
personnel.
4.
Reconnect power cable to entry panel.
For Readiness
Reporting,
Equipment Is
Not Ready/
Available If:
Curtains
damaged.
1-23