TM 5-6675-313-14
Table 1-5. DIRECT/GENERAL SUPPORT TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
PERSONNEL/CARGO DOORS DO NOT CLOSE COMPLETELY.
step 1.
Check that latch rollers rotate freely.
Replace latches (paragraph 1-20.2).
Step 2.
Check to see if latch rods are bent.
Replace latch rods (paragraph 1-20.2).
Step 3.
Check to see if door gasket is torn or broken.
Replace door gasket (paragraph 1-20.3)
2.
PERSONNEL/CARGO DOORS DO NOT LATCH PROPERLY.
Check door latch for missing or damaged components.
Replace door latch (paragraph 1-20.2)
3.
AIR OR WATER ENTERS SECTION AROUND DOOR.
Check to see if door gasket if worn or broken.
Replace door gasket (paragraph 1-20.3)
4.
RECEPTACLES DO NOT OPERATE BUT CIRCUIT BREAKERS ARE ON.
WARNING
Turn off main circuit breaker before inspecting or servicing circuit breakers
or receptacles.
Failure to do so may result in death or serious injury.
Step 1.
Check to see if power cable is firmly connected to power entry
panel.
Connect power cable.
1-87