TM 5-3610-287-24
2-17.
REPLACE STRAP AND BUCKLE ASSEMBLY (CONT)
WARNING
HAZARD. Turn off main power switch and
q ELECTRICAL
disconnect main power cable before-removing power entry
panel cover. Failure to do so could result in death or
serious injury.
VOLTAGE. Do not drill out rivets until power entry
q HIGH
panel cover is removed. Electrical power cords carrying
high voltage are directly behind cover, and could contact
drill bit, causing death or serious injury.
4.
Set MAIN POWER switch to OFF and disconnect main power cable.
Remove screws (6), lockwashers, flatwashers, and power entry panel
5.
cover (7).
Drill out rivets (8) securing loop strap fastener (9) to cover (7).
6.
7.
Remove strap and buckle assembly (1) from fastener (9).
INSTALLATION
1.
Thread loop strap fastener (9) through strap and buckle assembly (1).
2.
Install loop strap fastener (9) on cover (7) with rivets (8).
3.
Install power entry panel cover (7) with screws (6).
WARNING
ELECTRICAL HAZARD. Do not connect power cable to Section
before grounding. Failure to observe this warning may result
in death or serious injury.
4.
Connect main power cable and set MAIN POWER switch to ON.
Thread loop strap fastener (5) through strap (2).
5.
6.
Install fastener (5) with screws (4).
7.
Secure tool box (3) to floor with strap and buckle assembly (1) and
strap (2).
2-47