TM 5-3610-287-10
Preventive Maintenance Checks and Services (Cont)
Table 2-1.
A - After Operation
D - During Operation
B - Before Operation
Q - Quarterly
M - Monthly
w - Weekly
Equipment Is
Item To Be Inspected
Item
Not Ready/
NO.
Procedure
Available If:
Section Interior (Cont)
EXPANDING SIDE POWER CABLES.
Expanding side
16
power cables
Inspect power cables for
are damaged.
damage and fraying. Check
terminals for corrosion and
secure mounting in
Phase monitor
PHASE MONITOR METER. Inspect
17
meter malfunc-
tions.
for proper functioning.
Check that LED lights and
that fuse is not burned out.
TELEPHONE INSTALLATION.
18
Inspect binding posts for
proper wire connections.
Check that telephone is
securely mounted on Section
wall.
Hoist cables
HANDWINCH ASSEMBLIES.
19
are frayed.
Inspect handwinches and
Hooks are
missing or
tion and security of
cracked.
mounting. Refer to LO
5-3610-287-12 for lubrication
instructions. Inspect hoist
cables and hooks for frays or
cracks.
LOAD CENTER. Inspect circuit
Circuit breaker
20
is defective.
breakers. Turn each circuit
Load center is
breaker on, off, and back on.
damaged or
Inspect load center for
defective.
damage, insecure mounting, or
missing screws.
2-13