TM 5-3610-286-20
Table 2-5. Organizational Troubleshooting (cont).
Malfunction
Test or inspection
Corrective action
4. FEEDER BOARD DOES NOT RAISE INTO POSITION (cont).
NOTE
Step 7 requires one person to depress main pileup pushbutton during
performance.
Step 7.
Using a multimeter set to range higher than 115V ac, check for 115V ac between
the points listed below for each component.
Contactor c5: Point A1 and Point A2
Relay d227: Point 13 and Point 14
Contactor c6: Point 21 and Point 22
Contactor c5a: Point 13 and Point 14
Relay d103: Point 21 and Point 22
Relay d107: Point 71 and Point 72
If no voltage is observed, replace the faulty component (para. 2-93).
If voltage is observed, replace pile lift motor (para. 2-90).
NOTE
Use same procedure for auxiliary pile motor circuit. Refer to figure FO-1 for
associated components and test points.
5. FEEDER BOARD DOES NOT LOWER INTO POSITION.
WARNING
HIGH VOLTAGE
Do not operate printing press until you are sure TSS Press Section is
connected to a suitable ground. Failure to do so may result in death or
serious injury.
Shut off power source before attempting to disconnect, service, or connect
wires or cables. Failure to do so may result in death or serious injury.
2-28