TM 5-3610-286-20
2-85.
Suction Head Assembly (cont).
(2) Microswitch b92 adjustment. (figure 2-239)
NOTE
If microswitch b92 has been replaced, check and adjust switching point.
(a) Turn press main switch to ON position.
(b) Turn feeder by hand until governor foot (1) of suction head is at its lowest position.
(c) Lift governor foot (1) 2 mm. A microswitch click shouid be heard. if not, loosen
counter nut (2) and turn hex screw (3) until switch clicks when governor foot is raised
2 mm. Tighten counter nut.
NOTE
FOLLOW-ON MAINTENANCE:
(1) Install universai joint shaft (para. 2-84).
(2) Install suction head valve housing (TM 5-3610-286-10, para. 3-13).
2-484