TM 5-3610-285-14
Table 10-3. TROUBLESHOOTING-Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
DARKROOM SAFELIGHT WILL NOT LIGHT-Cont
Step 3. Check for defective lamp.
(a) Replace lamp (paragraph 10-10.2).
(b) If new lamp does not correct problem, refer to organizational maintenance.
3.
VACUUM CLEANER MOTOR DOES NOT OPERATE.
Step 1. Check power cord.
(a) If plugged in, proceed to step 2.
(b) Plug in power cord.
Step 2. Check position of power switch.
(a) If turned on, proceed to step 3.
(b) Turn power switch on.
Step 3. Check circuit breaker position in circuit breaker box.
(a) If turned off or tripped, turn circuit breaker on.
(b) If turned on, refer to supervisor.
Step 4. Check that vacuum cleaner is plugged into active outlet. Turn switch on.
If motor does not operate, replace vacuum cleaner.
4.
CONTACT PRINTING LAMP WILL NOT LIGHT.
Step 1. Check power cord.
(a) If plugged in, proceed to step 2.
(b) Plug in power cord.
10-23