TM 5-3610-285-14
Table 6-2. TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. HALATION OCCURS; APPEARS AS DOT SPREADING; COPY ENLARGED AT EDGES; SHADOWS ON TYPE-
Cont
Step 5. Check setting of intensity dial for contact printing lamp.
(a) If intensity dial setting correct, refer to operating procedures.
(b) Readjust intensity setting.
3. BROKEN IMAGES.
Step 1. Check stripped flat for tape or opaquing solution covering portion of image that is broken.
(a) If stripped flat is correctly prepared, proceed to step 2.
(b) Correctly prepare flat.
Step 2. Check that glass frame is clean.
(a) If glass frame is clean, proceed to step 3.
(b) Clean glass frame.
Step 3. Check exposure with sensitivity/contact control guide.
(a)
If exposure correct, problem may be due to flat being dirty.
Clean flat.
(b) Reset exposure controls.
6-10. MAINTENANCE PROCEDURES. There are no operator maintenance procedures assigned for this equipment.
6-25