TM 5-3610-285-14
NOTE
Striped pump wire is to remain unconnected.
q.
Splice new wiring, color to color, to wiring extending from conduit. Tape splices securely, and feed excess wire
into conduit.
r.
Reinstall conduit into buffer tank bracket and secure with conduit nut.
s.
Reinstall cover on buffer tank and secure with screws, lockwashers, and flat washers.
CAUTION
Exercise care when reinstalling buffer tank to ensure that quick-release valve is not damaged.
t.
Carefully reinstall buffer tank beneath replenisher tank stand. Secure to floor with lag bolts.
u.
Reinstall drain hose and RECYCLING VALVE hose on buffer tank. Tighten hose clamps.
v.
Turn on CB7 on van's circuit breaker panel.
5-16.24 Replace 12 Volt Power Supply.
MOS: 35E, Special Electronic Devices Repairer
TOOLS:
Tool Kit, Electronic Repair
Flat Tip Screwdriver
Cross Tip Screwdriver
Soldering Iron
Solder
SUPPLIES: 12 Volt Power Supply
WARNING
Death or serious injury may occur from electrical shock unless circuit breaker is turned
off before beginning replacement of power supply.
a.
Turn off circuit breaker CB7 on van's circuit breaker panel.
b.
Unstrap and move chiller away from wall.