TM 5-3610-285-14
c.
Loosen hose connectors at pump; drain hoses into pail. Tag and remove hoses and connectors.
d.
Remove two screws, cover, and insulation from electrical junction box.
e.
Tag and cut recirculation pump wires inside junction box.
f.
Unscrew cap from top of junction box and remove pump wiring. Remove wire ties.
g.
Remove retaining bolts, lockwashers, and defective pump from wall.
h.
Install new pump on wall and secure with bolts and lockwashers.
CAUTION
To prevent equipment damage, ensure that hoses are reconnected in proper positions.
i.
Reconnect hoses and tighten connectors securely.
j.
Install new wire ties on new pump cable, and insert cable into junction box. Replace cap.
k.
Connect new pump wiring with wire nuts.
l.
Reinstall cover and insulation on junction box and secure with screws.
m.
Open WATER SUPPLY valve.
n.
Turn on CB7 on van's circuit breaker panel.
5-173