f. Drain water and recirculation tanks in accordance with local directions.
WARNING
Death or serious injury may occur from electrical shock if power cable is disconnected while power is on.
g. Turn equipment switches OFF.
h. Turn main circuit breaker OFF.
i. Turn safety switch OFF.
j. Have power cable disconnected at power supply end. Disconnect power cable from receptacle. Put cable in storage
box on trailer chassis.
k. Turn emergency light switch OFF.
l. Disconnect telephone cables from power entry panel.
CAUTION
To prevent loss of rod or thread damage, do not allow ground rod to rotate and unscrew when removing
the slide hammer rod.
m. Remove ground rod with slide hammer, and put ground rods, couplings, and slide hammer inside section. Clean
threads on each ground rod before storing.
NOTE
Be certain exhaust fan covers and air vent cover are securely closed.
n. Reinspect section interior for loose equipment and close all vents.
o. Close section. Secure and lock all personnel doors and cargo door.
NOTE
Be sure air conditioner/heater covers are down and secured.
p. Remove handrails from boarding ladders.
q. Remove boarding ladders and insert handrails into back of ladders.
r. Secure ladders to back of section.
1-35