TM 5-3610-285-14
b.
Remove left access panel and top cover.
c.
Remove fixer and developer pump cover.
d.
Remove four circuit board cover mounting screws.
e.
Tag and disconnect wiring from circuit board.
f.
Remove circuit board.
g.
Install new circuit board.
h.
Reconnect wiring to circuit board.
i.
Reinstall circuit board cover to bracket and retain with four screws.
j.
Turn on processor circuit breaker.
k.
Adjust developer temperature (refer to Table 5-3, Item 2).
l.
Reinstall left access panel, pump cover, and top cover.
5-141