TM 5-3610-285-14
Table 5-5. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
BLOWER DOES NOT BLOW AIR WHEN MAIN DRIVE AND DRYER SWITCHES ARE ON, AND STANDBY
FEATURE IS NOT ON - Cont
WARNING
Electrical shock hazard. You must stand on rubber matting while performing this procedure.
Step 3. Check voltage between terminal board connector 4-34 and ground.
(a)
If 12 V dc is present, proceed to step 4.
(b)
If voltage is not present, replace DRYER and DEV. HEAT switch (paragraph 5-16.5).
5-105