TM 5-3610-285-14
h.
Install rack assemblies in processor.
i.
Turn ON MAIN DRIVE switch on front panel. Switch STANDBY RESET switch to OPERATING MODE
and run unit for amount of time recommended by manufacturer of cleaning solution.
CAUTION
To prevent flooding and/or damage to sump pump, open only one drain valve at a time.
j.
Drain system by opening DEV and FIX drain valves. Close valves after draining.
k.
Remove and clean wash, fixer, and developer rack assemblies.
l.
Fill wash, developer, and fixer tanks with clean water.
m.
Turn ON MAIN DRIVE switch. Turn STANDBY RESET switch to OPERATING MODE and run unit for
15 minutes. Turn OFF MAIN DRIVE switch.
CAUTION
To prevent flooding and/or damage to sump pump, open only one drain at a time.
n.
Open DEV, FIX, and WASH drain valves, and drain system. Close valves.
o.
Reinstall wash, fixer, and developer rack assemblies.
p.
Refill tanks with clean water.
q.
Turn ON MAIN DRIVE switch and turn STANDBY RESET switch to OPERATING MODE. Allow unit to
run for 10 minutes. Turn OFF MAIN DRIVE switch.
CAUTION
To prevent flooding and/or damage to sump pump, open only one drain valve at a time.
r.
Open DEV, FIX, and WASH drain valves, and drain system. Close all valves.
s.
Install new developer filter element (paragraph 5-10.1).
CAUTION
Use splash guard when filling developer and fixer tanks to prevent contamination of solutions.
t.
Refill tanks with fresh developer and fixer solutions.
5-75