1-6. OPERATION UNDER USUAL CONDITIONS . Operation of the Photomechanical Section consists of activation of
power after the section has been located at the operation site and 12 V dc power disconnected.
1-6.1 Preparation for Use.
a. Procedures for leveling.
CAUTION
Trailer-mounted section must be on surface that is approximately level to avoid unnecessary stress or
twisting of chassis when section is leveled.
NOTE
Snow or ice should be removed from under leveling foot plate before attempting to level section.
Sand, soft ground, or mud requires that shoring or scrap material be placed under leveling foot plate to
increase surface area and prevent from sinking into surface.
Be sure that air suspension is deflated as indicated in TM 5-2330-305-14.
(1)
Deflate air suspension in accordance with TM 5-2330-305-14.
1-24