TM 5-3610-285-14
2-16.21 Flush Vacuum Pump(s).
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS:
Tool Kit, Light Machine Repair
Flat Tip Screwdriver
Hex Head Key Wrench Set
Tool Kit, Precision
Permanent Magnet
SUPPLIES: Nonflammable Flushing Solvent (Item 54, Appendix E)
Rubber Matting
WARNING
Electrical shock hazard. You must stand on rubber matting while performing this procedure. Death or serious injury
may occur.
Always wear eye/face protective equipment when using solvent to prevent injury to eyes.
Fumes and chemicals used in flushing vacuum pump may result in serious injury if personnel do not operate
equipment with proper ventilation.
a.
Turn off power panel circuit breaker.
b.
Remove two screws and lower cabinet panel.
2-94