2-7.
OPERATION UNDER UNUSUAL CONDITIONS. This equipment is designed for operation only in a
controlled environment.
Section III. OPERATOR MAINTENANCE
2-8.
LUBRICATION INSTRUCTIONS . This equipment does not require lubrication.
2-9.
TROUBLESHOOTING PROCEDURES.
a.
The table lists the common malfunctions which you may find during the operation or maintenance of the flip-
top platemaker, or its components. You should perform the test/inspections and corrective actions in the order listed.
b.
This manual cannot list all malfunctions that may occur, nor all test or inspections and corrective actions. If a
malfunction is not listed or is not corrected by listed corrective actions, notify your supervisor.
Table 2-2. TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. FLIP-TOP PLATEMAKER DOES NOT ENERGIZE.
Step 1. Check that lower cabinet door is closed tightly.
(a)
If door tightly closed, proceed to step 2.
(b)
Close lower cabinet door tightly.
Step 2. Check that master circuit breaker in platemaker not tripped.
(a)
If circuit breaker not tripped, proceed to step 3.
(b)
Reset circuit breaker.
Step 3. Check position of power panel circuit breaker.
(a)
Reset circuit breaker.
(b)
If circuit breaker is on, refer to organizational maintenance.
2-31