TM 5-3610-259-14
1.4.5.8 REPLACE VENTILATION FAN COVER.
TOOLS:
Drill and Bits
Rivet Gun
Scraper
SUPPLIES: Rivets
Ventilation Fan Cover
Gasket
Solvent PD-680
Adhesive
Rags
1.
Drill rivets out of hinged cover to remove ventilation fan.
2.
Remove fan cover.
WARNING
DRY CLEANING SOLVENT, P-D-680, USED TO CLEAN PARTS
IS POTENTIALLY DANGEROUS TO PERSONNEL AND PROPERTY.
AVOID REPEATED AND PROLONGED SKIN CONTACT. WEAR
SOLVENT-IMPERMEABLE GLOVES AND EYE/FACE PROTECTIVE
EQUIPMENT WHEN USING SOLVENT. DO NOT USE NEAR OPEN
FLAME OR EXCESSIVE HEAT.
FLASH POINT OF SOLVENT IS
100°F TO 138°F (38°C TO 59°C).
3.
Scrape gasket off van body and clean area with solvent.
4.
Secure new gasket to van body with adhesive.
5.
Align new ventilation fan cover and rivet to hinge.
6.
Test cover for tightness of closure.
1-77