TM 5-3610-259-14
Table 1-5.
ORGANIZATIONAL TROUBLESHOOTING (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
NO POWER TO EQUIPMENT - Cont
Step 2.
Check circuit breaker input for 120 V ac.
(a) If input voltage is
(b) If input voltage is
support maintenance
wiring.
present, proceed to step 3.
not present, refer to direct/general
for repair or replacement of defective
Step 3.
Check circuit breaker output for 120 V ac.
(a) If output voltage is present, proceed to step 4.
(b) If output voltage is not present, refer to direct/general
support maintenance for circuit breaker replacement
(paragraph 1.5.3.5).
Step 4.
Remove receptacle and check for 120 V ac input.
(a) If present, replace receptacle (paragraph 1.4.5.5).
(b) If not present, refer to direct/general support maintenance
for repair or replacement of defective wiring.
1.4.5 MAINTENANCE PROCEDURES.
This section contains the step-by-step procedures
for performing Organizational Maintenance for the Van Body. Personnel required are
listed only if the task requires more than one. If personnel are not listed, it
means one person can do the task.
INDEX
PROCEDURE
PARAGRAPH
Replace Fluorescent Lamp Ballast . . . . . . . . . . . . . . . . . . . l 1.4.5.1
Replace Radio Frequency (RF) Filter . . . . . . . . . . . . . . . . . . . 1.4.5.2
Replace Fluorescent Light Switch . . . . . . . . . . . . . . . . . . . . 1.4.5.3
Replace On/OffSwitch . . . . . . . . . . . . . . . . . . . .1.4.5.4
Replace Receptacle . . . . . . . . . . . . . . . . . . . . . 1.4.5.5
1-63