TM 5-3610-259-14
Table 3-4.
ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. PLATE FINISHING TABLE WILL NOT ENERGIZE - Cont
(d) Check between negative lead of plug and right side of tubular
heater for zero ohms resistance.
(e) Check between ground lead of plug and brass screwhead (chassis
ground) next to input wires, for zero ohms resistance.
(1) If all checks are correct, proceed to step 2.
(2) If any check is not correct, replace power cord (paragraph
3-16-5).
Step 2.
Check continuity of blowers/heater switch.
(a) If continuity is incorrect, replace blowers/heater switch
(paragraph 3-16.1).
(b) If continuity is correct, refer to electrical diagram and
troubleshoot.
2. BLOWERS OPERATE BUT NO HEAT IS PRODUCED.
3-22